Toshiba Carrier VRF Systems

Carrier Commercial HVAC Systems.

Taking up less space than other commercial HVAC systems, Toshiba Carrier 3-pipe is available for heat recovery and 2-pipe for heat pump. The heat recovery system has the capability of using one flow selector box for each indoor unit which provides flexibility and longer pipe runs. Both systems use rotary compressors which are efficient at any speed, easy to maintain and function well in harsh environments.

Toshiba Carrier Single-Phase Heat Pump (MCY7).

Toshiba Carrier Single-Phase Heat Pump (MCY7)

The Toshiba Carrier VRF System is a combination of an outdoor unit with multiple style indoor units connected by refrigerant piping and wiring. The outdoor units have stacked dual condenser fan with side blow arrangement.

Product Features

  • 36,000 to 60,000 Btuh
  • 3.0 to 5.0 tons
  • Available in 3, 4 & 5-ton capacity range
  • 100% heating capacity at 5° F for 3, 4 ton and 80% heating capacity for 5 ton unit
  • Ability to connect up to 9 multiple style indoor units on a 5 ton system
  • 2-pipe heat pump system
  • High performance outdoor unit with Inverter-driven twin rotary compressor
  • 208/230-1-60Hz power supply
  • Cooling Operating Range: 23° F to 122° F
  • Heating Operating Range: -13° F to 60° F
  • Connected capacity up to 135%
  • Up to 21.5 SEER cooling efficiency
  • Up to 11.5 HSPF heating efficiency
  • Quiet outdoor operation

Reliability Features

  • All equipment wiring complies with NEC requirements
  • Unit constructed in accordance with ETL requirements
  • Finned tube heat exchanger
  • Suitable for R-410a refrigerant

Installation Features

  • Factory-provided controls
  • Single point electric connections

^ Back to Top

Toshiba Carrier Heat Recovery Outdoor Unit (MMYF).

Toshiba Carrier Heat Recovery Outdoor Unit (MMYF)

The Toshiba Carrier VRF system is a combination of an outdoor unit with multiple style indoor units connected by refrigerant piping and wiring. The outdoor units can be used as a single, dual, or triple modules.

Product Features

  • 72,000 to 456,000 Btuh
  • 6.0 to 38.0 Tons
  • Available in 6, 8, 10, 12 and 14-ton single module which can be combined up to 38-tons capacity
  • Ability to connect up to 64 indoor units to triple module outdoor unit
  • 3-pipe heat recovery system
  • High performance outdoor units with all Inverter driven twin rotary compressor
  • DC Inverter condenser fan motor
  • 208/230-3-60Hz or 460-3-60Hz voltage
  • Cooling ambient operating temperature is 14° F to 122° F and heating ambient operating temperature is -13° F to 60° F
  • Connected capacity is up to 150%
  • 13% smaller footprint with space saving models available in selected sizes

Reliability Features

  • All equipment wiring complies with NEC requirements
  • Unit constructed in accordance with ETL requirements
  • Unit performance is in accordance with AHRI 1230 standards
  • Compressor and condenser fan motor are Inverter driven
  • Finned tube heat exchanger
  • Suitable for R-410a refrigerant

Installation Features

  • Indoor units can be connected using Y-branch joints, branch headers, flow selector box or multiport flow selector box
  • Factory provided controls
  • Individual power connection for each module
  • Outdoor units are connected using twinning kits provided from factory

^ Back to Top

Toshiba Carrier Heat Recovery Outdoor Unit (MMYF-1P).

Toshiba Carrier Single-Phase Heat Recovery (MMYF-1P)

The Toshiba Carrier VRF system is a combination of an outdoor unit with multiple style indoor units connected by refrigerant piping and wiring. The Single-phase VRF heat recovery outdoor unit is a single module with the twinning capability up to 12 tons to achieve greater capacity.

Product Features

  • 72,000 to 144,000 Btuh
  • 6.0 to 12.0 Tons
  • Available in 6 ton single module which can be twinned up to 12-tons capacity
  • Ability to connect up to 25 indoor units
  • 3-pipe heat recovery system
  • High performance outdoor units with all Inverter driven twin rotary compressor
  • DC inverter condenser fan motor
  • 208/230-1-60Hz voltage
  • Cooling ambient operating temperature is 14° F to 122° F and heating ambient operating temperature is -13° F to 60° F
  • Connected capacity is up to 150%

Reliability Features

  • All equipment wiring complies with NEC requirements
  • Unit constructed in accordance with ETL requirements
  • Unit performance is in accordance with AHRI 1230 standards
  • Compressor and condenser fan motor are Inverter driven
  • Finned tube heat exchanger
  • Suitable for R-410a refrigerant

Installation Features

  • Indoor units can be connected using Y-branch joints, branch headers, flow selector box or multiport flow selector box
  • Factory provided controls
  • Individual power connection for each module
  • Outdoor units are connected using twinning kits provided from factory

^ Back to Top

Toshiba Carrier Heat Pump Outdoor Unit (MMYH).

Toshiba Carrier Heat Pump Outdoor Unit (MMYH)

The Toshiba Carrier VRF System is a combination of an outdoor unit with multiple style indoor units connected by refrigerant piping and wiring. The outdoor units can be used in single, dual or triple modules.

Product Features

  • Single, dual or triple module heat pump system
  • 72,000 to 456,000 Btuh
  • 6.0 to 38.0 Tons
  • Available in 6, 8, 10, 12 and 14-ton single module which can be combined up to 38-tons capacity
  • Ability to connect up to 64 indoor units to triple module outdoor unit
  • 2-pipe heat pump system
  • High performance outdoor units with all Inverter driven twin rotary compressor
  • DC Inverter condenser fan motor
  • 208/230-3-60Hz or 460-3-60Hz voltage
  • Cooling ambient operating temperature is 14° F to 122° F and heating ambient operating temperature is -13° F to 60° F
  • Connected capacity is up to 150%
  • 9% smaller footprint with space saving models available in selected sizes

Reliability Features

  • All equipment wiring complies with NEC requirements
  • Unit constructed in accordance with ETL requirements
  • Unit performance is in accordance with AHRI 1230 standards
  • Compressor and condenser fan motors are inverter driven
  • Finned tube heat exchanger
  • Suitable for R-410a refrigerant

Installation Features

  • Indoor units can be connected using Y-branch joints and branch headers
  • Factory-provided controls
  • Individual power connection for each module
  • Outdoor units are connected using twinning kits provided from factory

^ Back to Top

Toshiba Carrier VRF Rooftop Unit (40QQ).

Toshiba Carrier VRF Rooftop Unit (40QQ)

The Toshiba Carrier Variable Refrigerant Flow (VRF) rooftop unit is ideal for new construction as well as for existing rooftop replacement application. Options like electric heat, horizontal or vertical discharge, economizer and use of existing curb make a replacement job go faster and cost effective with minimal down time.

Product Features

  • 36,000 to 60,000 Btuh
  • 3.0 to 5.0 tons
  • Available in 3, 4 & 5 ton capacity
  • Single phase power supply - 208/230-1-60 & 460-1-60
  • Direct drive, ECM motor
  • Max external static pressure up to 1.65
  • Pre painted exterior panels and primer-coated interior panels tested to 500 hour salt spray protection
  • Two-inch disposable returns air filters
  • Full perimeter base rail with built in rigging adapters for fork trucks slot
  • ASHRAE 15 & 34
  • Title 24 of the California Code Of Regulations
  • Light weight compared to standard rooftop unit
  • Use existing roof curb
  • Increased efficiency
  • Unit is shipped with mounting bracket for flow selector box as standard for heat recovery system
  • Optional features like electric heat & economizer are available from factory for field installation

Reliability Features

  • Finned tube heat exchanger
  • Suitable for R410a refrigerant
  • All equipment wiring complies with NEC requirements
  • Unit constructed in accordance with UL and UL, Canada standards

Installation Features

  • Same foot print as installed Carrier 3-5 ton rooftops back to 1989, reducing installation costs and time
  • Field convertible from vertical to horizontal airflow for slab mounting
  • Unit is shipped with mounting bracket for flow selector box as standard for heat recovery system
  • Factory provided controls
  • Single point electric connections

^ Back to Top

Toshiba Carrier VRF Rooftop Unit w/Vane Axial Fan (40QQ-E).

Toshiba Carrier VRF Rooftop Unit w/Vane Axial Fan (40QQ-E)

The Toshiba Carrier Variable Refrigerant Flow (VRF) rooftop unit with Vane Axial Fan (VAF) technology is ideal for existing rooftop replacement application. Options like electric heat with single-point power connection, horizontal or vertical discharge, economizer and use of existing curb can help make a replacement job go faster and become more cost effective with minimal down time.

Product Features

  • 36,000 to 60,000 Btuh
  • 3.0 to 5.0 tons
  • Available in 3, 4 & 5 ton capacity
  • Single phase power supply - 208/230-1-60 & 460-1-60
  • Direct drive, ECM motor
  • Max external static pressure up to 1.2
  • Pre painted exterior panels and primer-coated interior panels tested to 500 hour salt spray protection
  • Two-inch disposable returns air filters
  • Full perimeter base rail with built in rigging adapters for fork trucks slot
  • ASHRAE 15 & 34
  • Title 24 of the California Code of Regulations
  • Light weight compared to standard rooftop unit
  • Use existing roof curb
  • Increased efficiency
  • Unit is shipped with mounting bracket for flow selector box as standard for heat recovery system
  • Optional features like electric heat & economizer are available from factory for field installation

Reliability Features

  • Finned tube heat exchanger
  • Suitable for R410a refrigerant
  • All equipment wiring complies with NEC requirements
  • Unit constructed in accordance with UL and UL, Canada standards

Installation Features

  • Same foot print as installed Carrier 3-5 ton rooftops back to 1989, reducing installation costs and time
  • Field convertible from vertical to horizontal airflow for slab mounting
  • Unit is shipped with mounting bracket for flow selector box as standard for heat recovery system
  • Factory provided controls
  • Single point electric connections

^ Back to Top

Toshiba Carrier Vertical AHU (40TCQ).

Toshiba Carrier Vertical AHU (40TCQ)

The Toshiba Carrier Vertical Air Handling Unit is ideal for closet applications. The Vertical Air Handling unit is also a multi-positional unit - vertical and horizontal.

Product Features

  • 24,000 to 48,000 Btuh
  • 2.0 to 4.0 tons
  • Available in five different capacities
  • 208-230V/1/60Hz voltage
  • Energy efficient ECM
  • Three fan speeds - high, medium, low
  • Multi-position installation, vertical standing or laid horizontally
  • Precise airflow delivery across a wide range of duct static pressure
  • Pre painted 20g galvanized cabinet
  • 1" filter rack

Reliability Features

  • Finned tube heat exchanger
  • Suitable for R410a refrigerant
  • All equipment wiring complies with NEC requirements
  • Unit constructed in accordance with ETL and ETL, Canada standards

Installation Features

  • Factory provided controls
  • Single point electric connections

^ Back to Top

Toshiba Carrier Underceiling Indoor Unit (MMC1).

Toshiba Carrier Underceiling Indoor Unit (MMC1)

The Toshiba Carrier Underceiling indoor unit is exposed under the ceiling.

Product Features

  • 18,000 to 42,000 Btuh
  • 1.5 to 3.5 Tons
  • Available in 4 different capacities
  • 208-230V/1/60Hz voltage
  • DC fan motor
  • Three fan speeds - High, Medium, Low
  • Auto louver control
  • Optional condensate drain pump and elbow kit
  • Knock-out for OA opening

Reliability Features

  • Finned tube heat exchanger
  • Suitable for R-410a refrigerant
  • All equipment wiring complies with NEC requirements
  • Unit constructed in accordance with ETL and ETL, Canada standards

Installation Features

  • Elbow kit can be ordered along with drain pump kit for vertical discharge of condensate
  • Factory provided controls
  • Single point electric connections

^ Back to Top

Toshiba Carrier Outside Air Indoor Unit (MMD1).

Toshiba Carrier Outside Air Indoor Unit (MMD1)

The Outside Air unit draws in ventilation air into the space to provide fresh air. The units are installed in plenum and can be connected to a heat pump system along with other styles of indoor unit.

Product Features

  • 48,000 to 96,000 Btuh
  • 4.0 to 8.0 tons
  • Available in three different capacities
  • 208/230V/1/60Hz voltage
  • DC fan motor
  • Three motor speeds - High, Medium, Low
  • Three external static pressure setting
  • Up to 1.1" of external setting

Reliability Features

  • Finned tube heat exchanger
  • Suitable for R-410A refrigerant
  • All equipment wiring complies with NEC requirements
  • Unit constructed in accordance with ETL

Installation Features

  • Factory provided controls
  • Single point electric connections

^ Back to Top

Toshiba Carrier High Static Duct Indoor Unit (MMD4).

Toshiba Carrier High Static Duct Indoor Unit (MMD4)

Toshiba Carrier High Static Ducted indoor units can handle higher static to support longer ductwork for a given space and are ideal for hideaway applications serving multiple zones.

Product Features

  • 30,000 to 96,000 Btuh
  • 2.5 to 8.0 Tons
  • Available in 5 different capacities
  • 208-230V/1/60Hz voltage
  • Up to 1" of external static
  • AC fan motor
  • Single fan speed

Reliability Features

  • Finned tube heat exchanger
  • Suitable for R-410a refrigerant
  • All equipment wiring complies with NEC requirements
  • Unit constructed in accordance with ETL and ETL, Canada standards

Installation Features

  • Factory provided controls
  • Single point electric connections

^ Back to Top

Toshiba Carrier Concealed Duct Indoor Unit (MMDB).

Toshiba Carrier Concealed Duct Indoor Unit (MMDB)

The Toshiba Carrier Concealed Duct indoor unit is ideal for single room hideaway applications.

Product Features

  • 7,500 to 48,000 Btuh
  • 0.6 to 4.0 Tons
  • Available in 11 different capacities
  • 208-230V/1/60Hz voltage
  • External static range 0.2" to 0.48"
  • DC fan motor
  • Three fan speeds - High, Medium, Low
  • 1" filter rack for field installed filter
  • Built-in condensate drain pump
  • Rear return is standard and bottom return is field convertible
  • Optional fan guard

Reliability Features

  • Finned tube heat exchanger
  • Suitable for R-410a refrigerant
  • All equipment wiring complies with NEC requirements
  • Unit constructed in accordance with ETL and ETL, Canada standards

Installation Features

  • Factory provided controls
  • Single point electric connections

^ Back to Top

Toshiba Carrier Slim Duct Indoor Unit (MMDP).

Toshiba Carrier Slim Duct Indoor Unit (MMDP)

The Toshiba Carrier Slim Duct indoor units are ideal for soffitt or low plenum height applications.

Product Features

  • 7,500 to 18,000 Btuh
  • 0.6 to 1.5 Tons
  • Available in 5 different capacities
  • 208-230V/1/60Hz voltage
  • Less than 0.2" of external static
  • DC fan motor
  • Three fan speeds - High, Medium, Low
  • Built in condensate drain pump
  • OA knock out
  • Optional auxiliary fresh air kit

Reliability Features

  • Finned tube heat exchanger
  • Suitable for R-410a refrigerant
  • All equipment wiring complies with NEC requirements
  • Unit constructed in accordance with ETL and ETL, Canada standards

Installation Features

  • Factory provided controls
  • Single point electric connections

^ Back to Top

Toshiba Carrier Vertical AHU (MMDV).

Toshiba Carrier Vertical AHU (MMDV)

The Toshiba Carrier Vertical Air Handling unit is ideal for closet applications. The Vertical Air Handling unit is also multi-positional unit - vertical and horizontal right discharge.

Product Features

  • 12,000 to 60,000 Btuh
  • 1.0 to 5.0 tons
  • Available in eight different capacities
  • 208/230-1-60Hz power supply
  • Energy efficient ECM
  • Three fan speeds - high, medium, low
  • Multi-position installation, vertical standing or placed horizontally
  • Max static pressure of 0.8" ESP (based on size)
  • Exterior Panel - 19 to 22 gauge galvanized with baked on polyester powder coating
  • ½" fiberglass insulation as standard
  • 1" MERV 3 filter as standard
  • Factory-supplied, field-installed electric heater, filter and filter racks, and return air plenum
  • Quiet operation

Reliability Features

  • Finned tube heat exchanger
  • Suitable for R-410a refrigerant
  • All equipment wiring complies with NEC requirements
  • Unit constructed in accordance with ETL requirements

Installation Features

  • Factory provided controls
  • Single point electric connections

^ Back to Top

Toshiba Carrier High Wall Indoor Unit (MMK3).

Toshiba Carrier High Wall Indoor Unit (MMK3)

The Toshiba Carrier High Wall indoor unit is aesthetically pleasing and blends with any room interior decor while efficiently heating and cooling the space.

Product Features

  • 7,500 to 24,000 Btuh
  • 0.6 to 2.0 Tons
  • Available in 6 different capacities
  • 208-230V/1/60Hz voltage
  • DC fan motor
  • Three fan speeds - High, Medium, Low
  • 70° directional auto swing louver

Reliability Features

  • Finned tube heat exchanger
  • Suitable for R-410a refrigerant
  • All equipment wiring complies with NEC requirements
  • Unit constructed in accordance with ETL and ETL, Canada standards

Installation Features

  • Installation plate provides ease of unit installation
  • Factory provided controls
  • Single point electric connections

^ Back to Top

Toshiba Carrier Exposed Floor Console Indoor Unit (MML4).

Toshiba Carrier Exposed Floor Console Indoor Unit (MML4)

The Floor Console - Exposed units are installed flush against a wall, typically under a window or in a room with an exterior wall.

Product Features

  • 7,500 to 24,000 Btuh
  • 0.6 to 2.0 Tons
  • Available in six different capacities
  • 208/230V-1-60Hz
  • AC fan motor
  • Three fan speeds - High, Medium, Low
  • Options for routing power wiring, refrigerant and drain lines
  • Field changeable front discharge to top discharge

Reliability Features

  • Finned tube heat exchanger
  • Suitable for R-410a refrigerant
  • All equipment wiring complies with NEC requirements
  • Unit constructed in accordance with ETL requirements

Installation Features

  • Factory provided controls
  • Single point electric connections

^ Back to Top

Toshiba Carrier Recessed Floor Console Indoor Unit (MMLB).

Toshiba Carrier Recessed Floor Console Indoor Unit (MMLB)

The recessed floor console units can be installed inside a wall or custom-built cabinet to match interior space design.

Product Features

  • 7,500 to 24,000 Btuh
  • 0.6 to 2.0 Tons
  • Available in six different capacities
  • 208/230V-1-60Hz
  • AC fan motor
  • Three fan speeds - High, Medium, Low
  • Fully recessed floor standing wall unit

Reliability Features

  • Finned tube heat exchanger
  • Suitable for R-410a refrigerant
  • All equipment wiring complies with NEC requirements
  • Unit constructed in accordance with ETL requirements

Installation Features

  • Factory provided controls
  • Single point electric connections

^ Back to Top

Toshiba Carrier 4-Way Cassette Indoor Unit (MMU2).

Toshiba Carrier 4-Way Cassette Indoor Unit (MMU2)

The Toshiba Carrier 4-Way Cassette indoor unit delivers air in all four directions to evenly condition a space.

Product Features

  • 7,500 to 42,000 Btuh
  • 0.6 to 3.5 Tons
  • Available in 10 different capacities
  • 208-230V/1/60Hz voltage
  • Delivers air in all four directions
  • DC fan motor
  • Three fan speeds - High, Medium, Low
  • Knock out for OA opening
  • Knock out for branch ducting supply
  • Louver control (fixed or swing)
  • Built in condensate drain pump
  • Optional height spacer, air discharge kit, fresh air and auxiliary fresh air kit

Reliability Features

  • Finned tube heat exchanger
  • Suitable for R-410a refrigerant
  • All equipment wiring complies with NEC requirements
  • Unit constructed in accordance with ETL and ETL, Canada standards

Installation Features

  • Grille ships from factory for field installation
  • Factory provided controls
  • Single point electric connections

^ Back to Top

Toshiba Carrier Compact 4-Way Cassette Indoor Unit (MMUM).

Toshiba Carrier Compact 4-Way Cassette Indoor Unit (MMUM)

The Toshiba Carrier Compact 4-Way Cassette indoor unit delivers air in all four directions to evenly condition a space.

Product Features

  • 7,500 to 18,000 Btuh
  • 0.6 to 1.5 Tons
  • Available in 5 different capacities
  • 208-230V/1/60Hz voltage
  • Delivers air in all four directions
  • DC fan motor
  • Three fan speeds - High, Medium, Low
  • Knock out for OA opening
  • Built in condensate drain pump
  • Louver control (fixed or swing)
  • Optional fresh air kit

Reliability Features

  • Finned tube heat exchanger
  • Suitable for R-410a refrigerant
  • All equipment wiring complies with NEC requirements
  • Unit constructed in accordance with ETL and ETL, Canada standards

Installation Features

  • Grille ships from factory for field installation
  • Factory provided controls
  • Single point electric connections

^ Back to Top

Toshiba Carrier Touch Screen Central Controller (BMS-CT5120UL).

Toshiba Carrier Touch Screen Central Controller (BMS-CT5120UL)

The Touch Screen Central Controller is a line voltage controller mounted on the wall with a touch screen LCD display panel. This controller enables the customer to control and monitor the operation of the VRF System.

Features

  • Grouping based on floor, unit, area, tenant and level
  • Operating Mode, Turning ON/OFF
  • Enable or disable local remote control
  • Master scheduler: weekly, 5 special days, monthly
  • Display alarm + provide history for alarms
  • Web browser monitoring and control (for intranet PC)
  • Up to 2 concurrent users can be connected
  • Additional digital I/O device available
  • Maximum of 512 indoor units per Touch Screen Controller
  • Selectable display language - English/French/Spanish

^ Back to Top

Toshiba Carrier Micro BACNet Interface (BMS-IFBN640TLUL).

Toshiba Carrier Micro BACNet® Interface (BMS-IFBN640TLUL)

The BN Interface is a BACnet controller which enables the communication between the Building Automation System (BAS) and Toshiba Carrier VRF unit. This allows the customer to control the Toshiba Carrier VRF System from a centralized location.

Features

  • On/Off
  • Operation mode
  • Fan speed
  • Louver
  • Set temperature
  • Room temperature
  • Permit / Prohibit local operation
  • Error code
  • Error status
  • Filter sign
  • Ventilation On/Off
  • Ventilation mode

^ Back to Top

Toshiba Carrier BACnet System - TCS-NET Relay Interface (BMS-IFLSV4UL).

Toshiba Carrier BACnet® System - TCS-NET Relay Interface (BMS-IFLSV4UL)

The BACnet System enables the communication between the Building Automation System (BAS) and VRF unit, allowing the customer to control the Toshiba Carrier system from a centralized location.

System Functions

  • Open network protocol
  • Maximum of 128 indoor units per BACnet® System (up to 8 TCS-NET Relay Interfaces per BACnet system)
  • The TCS-NET Relay Interface is used to connect the VRF system to the BACnet system

Controlling Functions

  • ON/OFF
  • Operating mode
  • Temperature settings
  • Fan speed
  • Louver
  • Permit/prohibit local remote controller

Monitoring Functions

  • ON/OFF
  • Operating mode
  • Temperature settings
  • Fan speed
  • Louver
  • Permit/prohibit local remote controller
  • Error code/status

^ Back to Top

Toshiba Carrier BACnet® System - Intelligent Server (BMS-LSV6UL).

Toshiba Carrier BACnet® System - Intelligent Server (BMS-LSV6UL)

The BACnet System enables the communication between the Building Automation System (BAS) and VRF unit, allowing the customer to control the Toshiba Carrier system from a centralized location.

System Functions

  • Open network protocol
  • Maximum of 128 indoor units per BACnet® System (up to 8 TCS-NET Relay Interfaces per BACnet system)
  • The TCS-NET Relay Interface is used to connect the VRF system to the BACnet system

Controlling Functions

  • ON/OFF
  • Operating mode
  • Temperature settings
  • Fan speed
  • Louver
  • Permit/prohibit local remote controller

Monitoring Functions

  • ON/OFF
  • Operating mode
  • Temperature settings
  • Fan speed
  • Louver
  • Permit/prohibit local remote controller
  • Error code/status

^ Back to Top

Toshiba Carrier Smart Manager Centralized Controller (BMS-SM1280HTLUL).

Toshiba Carrier Smart Manager Centralized Controller (BMS-SM1280HTLUL)

The Smart Manager is a line voltage controller mounted on the wall that enables the customer to control and monitor the operation of the VRF System by using an onsite computer.

System Functions

  • Display all units on one screen
  • Shows basic indoor unit setting on main screen
  • Advance operation and master scheduling functions are available
  • Up to four concurrent web browser users can be connected simultaneously
  • Up to 32 user accounts can be programmed with different levels of access (at least one user must be at administrator level)
  • Energy monitoring and report creation functions available
  • Advance operation and master schedules can be set on a calendar
  • Additional digital I/O device available
  • Thin profile controller and separate power supply unit enables easy installation
  • Maximum of 128 indoor units per Smart Manager (requires 2 TCC links - 64 units on each link)

^ Back to Top

Toshiba Carrier BACnet System - Server Software (BMS-STBN10UL).

Toshiba Carrier BACnet® System - Server Software (BMS-STBN10UL)

The BACnet System enables the communication between the Building Automation System (BAS) and VRF unit, allowing the customer to control the Toshiba Carrier system from a centralized location.

System Functions

  • Open network protocol
  • Maximum of 128 indoor units per BACnet® System (up to 8 TCS-NET Relay Interfaces per BACnet system)
  • The TCS-NET Relay Interface is used to connect the VRF system to the BACnet system

Controlling Functions

  • ON/OFF
  • Operating mode
  • Temperature settings
  • Fan speed
  • Louver
  • Permit/prohibit local remote controller

Monitoring Functions

  • ON/OFF
  • Operating mode
  • Temperature settings
  • Fan speed
  • Louver
  • Permit/prohibit local remote controller
  • Error code/status

^ Back to Top

Toshiba Carrier DX Interface (DX-INTERFACE).

Toshiba Carrier DX Interface (DX-INTERFACE)

DX interface enables integration to any 3rd party heat pump air handling unit (AHU) into the Toshiba Carrier SMMS-e and SHRM-e systems.

Features

  • Two different types of control methods:
    • Return Air (RA) control
    • 0-10V control

  • Five different types of Pulse Motor Valve kit to meet capacity requirements

^ Back to Top

Toshiba Carrier Flow Selector Box (FS-BOX).

Toshiba Carrier Flow Selector Box (FS-BOX)

Flow Selector boxes are required on the Toshiba Carrier VRF heat recovery system available in multiple styles and sizes. Combination of single port and multiport Flow Selector boxes provide ease and greater flexibility during piping layout for a given building.

Product Features

  • Available in three different styles - single port, single port (long) & multiport
  • Single port Flow Selector box is powered from indoor unit
  • Multiport Flow Selector box requires separate power supply
  • Multiport Flow Selector box is available in 4 or 6 port configuration

Reliability Features

  • Suitable for R-410a refrigerant
  • Wiring complies with NEC requirements
  • Unit constructed in accordance with ETL requirements

Installation Features

  • Single port Flow Selector box is powered from indoor unit
  • Multiport Flow Selector box requires separate power supply

^ Back to Top

Toshiba Carrier i-Vu Interface (OPN-MTCC).

Toshiba Carrier i-Vu® Interface (FOPN-MTCC)

The Toshiba Carrier VRF interface provides the capability to monitor or control a VRF system with multiple zones. When used with Carrier i-Vu®, a graphic is also provided for each zone to display zone information.

The OPN-MTCC is designed to make the integration to an i-Vu server (BMS system) as seamless as possible and has a built-in OpenLink.

The OpenLink has a pre-installed Snap file that will automatically associate all available control points.

Features

  • Grouping based on floor, unit, area, tenant and level
  • Operating Mode, Turning ON/OFF
  • Enable or disable local remote control
  • Master scheduler
  • Display alarm + provide history for alarms
  • Maximum of 64 indoor units
  • Maximum of 16 refrigeration system
  • Premium polycarbonate cabinet
  • Factory provided mounting feet

^ Back to Top

Toshiba Carrier Wired Remote Controller (Programmable) (RBC-AMS41UL).

Toshiba Carrier Wired Remote Controller (Programmable) (RBC-AMS41UL)

The Wired Remote Controller (Programmable) is a thermostat mounted on the wall that maintains room temperature by controlling unit operation.

Features

  • Scheduling functions
  • Controls up to 8 units
  • Operating modes: Heat, Dry, Cool, and Fan
  • Fan modes: Auto, High, Medium and Low
  • Temperature setting
  • Key lock function
  • Louver setting
  • Power supply: from indoor unit

^ Back to Top

Toshiba Carrier Wired Remote Controller (Programmable) (RBC-AMS54E-UL).

Toshiba Carrier Wired Remote Controller (Programmable) (RBC-AMS54E-UL)

The wired remote controller (programmable) is a low voltage thermostat mounted on the wall that maintains room temperature by controlling system operation.

Features

  • 1° F temperature indication
  • Simple, easy to use
  • Backlit
  • Fan Speed
  • Clock Setting
  • Schedule Timer
  • Dual Set-point
  • Key Lock
  • Set temperature range limiting
  • Group control up to 8 indoor units
  • Service check mode
  • Compatible with Toshiba Carrier RAV and VRF systems
  • Flow Selector Single Port Individual Control
  • Powered from indoor unit

^ Back to Top

Toshiba Carrier Wired Remote Controller (Non-Programmable) (RBC-AMT32UL).

Toshiba Carrier Wired Remote Controller (Non-Programmable) (RBC-AMT32UL)

The Wired Remote Controller (Non-Programmable) is a thermostat mounted on the wall that maintains room temperature by controlling unit operation.

Features

  • Controls up to 8 units
  • Operating modes: Heat, Dry, Cool, and Fan
  • Fan modes: Auto, High, Medium and Low
  • Temperature setting
  • Key lock function
  • Louver setting
  • Power supply: from indoor unit

^ Back to Top

Toshiba Carrier Simple Wired Remote Control (RBC-AS41UL).

Toshiba Carrier Simple Wired Remote Control (RBC-AS41UL)

The Simple Wired Remote Control is mounted on the wall, allowing remote sensing of room temperature along with user interface with the system.

Features

  • ON/OFF
  • Operating modes: Auto, Heat, Dry, Cool, and Fan
  • Fan modes: Auto, High, Medium and Low
  • Louver setting
  • Space temperature display
  • Power supply: from indoor unit

^ Back to Top

Toshiba Carrier Integral Receiver (4-Way Cassette) (RBC-AX32U-W-UL).

Toshiba Carrier Integral Receiver (4-Way Cassette) (RBC-AX32U-W-UL)

The Integral Receiver is a combination of a mounted receiver on an 4-way cassette indoor unit and handheld wireless remote that allows a user to interface with the unit.

Features

  • ON/OFF
  • Operating modes: Auto, Heat, Dry, Cool, and Fan
  • Fan modes: Auto, High, Medium and Low
  • Louver setting
  • Timer function
  • Error display

^ Back to Top

Toshiba Carrier Integral Receiver (Underceiling) (RBC-AX33CUL).

Toshiba Carrier Integral Receiver (Underceiling) (RBC-AX33CUL)

The Integral Receiver is a combination of a mounted receiver on an underceiling indoor unit and handheld wireless remote that allows a user to interface with the unit.

Features

  • ON/OFF
  • Operating modes: Auto, Heat, Dry, Cool, and Fan
  • Fan modes: Auto, High, Medium and Low
  • Louver setting
  • Timer function
  • Error display

^ Back to Top

Toshiba Carrier Stand-Alone Receiver (TCB-AX32UL).

Toshiba Carrier Stand-Alone Receiver (TCB-AX32UL)

The Stand-Alone Receiver is a combination of a wall/ceiling mounted receiver and a handheld wireless remote that allows a user to interface with the unit.

Features

  • ON/OFF
  • Operating modes: Auto, Heat, Dry, Cool, and Fan
  • Fan modes: Auto, High, Medium and Low
  • Louver setting
  • Timer function
  • Error display
  • Receiver power supply: from indoor unit
  • Remote power supply: 2 x AAA batteries

^ Back to Top

Toshiba Carrier LonWorks LN Interface (TCB-IFLN642TLUL).

Toshiba Carrier LonWorks® LN Interface (TCB-IFLN642TLUL)

The LonWorks® LN Interface enables the communication between the Building Management System (BAS) and VRF, allowing the customer to control the Toshiba Carrier system from a centralized location.

System Functions

  • SNVT signal
  • Maximum of 64 indoor units per LonWorks LN interface

Controlling Functions

  • ON/OFF
  • Operating mode
  • Temperature settings
  • Fan speed
  • Louver
  • Permit/prohibit local remote controller

Monitoring Functions

  • ON/OFF
  • Operating mode
  • Temperature settings
  • Fan speed
  • Louver
  • Permit/prohibit local remote controller
  • Error code/status

^ Back to Top

Toshiba Carrier 24V Interface (TCB-IFTH1GUL).

Toshiba Carrier 24V Interface (TCB-IFTH1GUL)

The 24V Interface allows third-party conventional thermostat to communicate and operate Toshiba Carrier Variable Refrigerant Flow (VRF) indoor fan coil units.

Controls Features

  • Connect third-party conventional thermostat to Toshiba Carrier Variable Refrigerant Flow (VRF) indoor fan coil units
  • Fan speed control: High, Medium & Low
  • Operational Mode: Cooling, Heating, Fan & Off

^ Back to Top

Toshiba Carrier ERV Control Interface (TCB-IFVN1UL).

Toshiba Carrier ERV Control Interface (TCB-IFVN1UL)

The ERV Control Interface is used to connect and operate third-party Energy Recovery Ventilation. The third-party ERV ON/OFF and fan speed is controlled using the Toshiba Carrier Wired Controller, which is connected to the Toshiba Carrier VRF system.

Controls Features

  • Connect and operate third-party Energy Recovery Ventilation (ERV)
  • Digital input/output
  • Non-polarity connection between interface and Wired Controller

^ Back to Top

Toshiba Carrier Remote Sensor (TCB-TC41LUL).

Toshiba Carrier Remote Sensor (TCB-TC41LUL)

The Remote Sensor is mounted on the wall, allowing remote sensing of room temperature without any user interface with the system.

Features

  • Prevents overcooling or overheating of the space
  • Power supply: from indoor unit

^ Back to Top